Loading...
Note/IllustrationAction
Lengthened screwdriverRemove the screws and pull the drive
unit out from the bottom.
4
xx2100001337
Refitting the drive unit
Refitting the drive unit
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 41.
2
xx2100001295
Continues on next page
138 Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.4 Replacing the drive unit
Continued