EasyManua.ls Logo

ABB OmniCore E10 - Page 142

ABB OmniCore E10
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteArticle numberEquipment
Content is defined in section
Standard toolkit for controller on
page 202.
-Standard toolkit
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC076810-008Circuit diagram - OmniCore E10
Removing the computer and logic unit
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 41.
2
xx2100001295
Removing the controller top cover on
page 120.
Remove the top cover of the controller.3
Disconnecting the connectors to the computer and logic unit
Note/IllustrationAction
Disconnect:
A2.X9 - T4.X3
A2.X10 - T4.X1
A1.X6 - A2.X11
A1.X13 - A2.X12
A2.X13 - G1/G2.X1
1
Continues on next page
142 Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.5 Replacing the computer and logic unit
Continued

Table of Contents

Related product manuals