EasyManua.ls Logo

ABB OmniCore E10 - Page 154

ABB OmniCore E10
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Required documents
NoteArticle numberDocument
3HAC076810-008Circuit diagram - OmniCore E10
Removing the incoming mains connector
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 41.
2
xx2100001295
Removing the controller top cover on
page 120.
Remove the top cover of the controller.3
Removing the incoming mains connector
Note/IllustrationAction
Disconnect:
Q0 - A1.X1.
Two ground cables which con-
nects to the left cabinet frame.
1
Pull the cable ties out from the locking
holes.
Tip
Take photos of the cable ties and locking
holes before pulling out, to have as a
reference when refitting the cable ties.
2
Continues on next page
154 Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the incoming mains connector
Continued