1-20 Hardware Specifications and Configurations
CPU Fan True Value Table (Tj=90)
System Memory
Memory Combinations
CPU Tj VGA Tj
FAN on (°C) FAN off (°C) FAN on (°C) FAN off (°C) dBA FAN speed (RPM)
T1 Default Default 23 1600
T2 65 60 65 60 25.4 2200
T3 71 66 71 66 26.8 2400
T4 77 72 77 72 30 2800
T5 85 80 85 80 31.7 3200
T6 90 86 90 86 32.3 3400
T7 95 CPU throttling point
T8 102 Critical shutdown by EC
Item Specification
Memory controller Built in CPU
Memory size 512MB,1GB,2GB,4GB DDR3 RAM
DIMM socket number 2
Supports memory size per socket 4GB
Supports maximum memory size 4GB
Supports DIMM type Supports DDR III 800/1066Mhz
SDRAM memory interface design
Supports DIMM Speed 800/1066 MHz
Support DIMM voltage 1.5 V
Supports DIMM package SODIMM
Slot 1 (MB) Slot 2 (MB) Total Memory (MB)
0 1024 1024
1024 0 1024
1024 1024 2048
0 2048 2048
2048 0 2048
2048 2048 4096
4096 0 4096
0 4096 4096
4096 4096 8192