1569PT060EE1 Rev.7 Page19of62
3.7.2 Connection of load cells 2 input
T060Eforeseesanoptionalsecondloadcellsinput.Theconsiderationsmadeforthemainchannelalsoapplyforthe
optionalinputchannel.
LC2
INDICATION FUNCTION TERMINAL
+A +Excitation 33
A Excitation 32
+S +Signal 31
S Signal 30
+R +Reference 29
R Reference 28
3128 29 30
-S
+R
-R
3432 33
+S
3635 37
-A
+A
3938
-R
+R
-S
+S
-A
+A
LOAD CELL 2 LOAD CELL 1
232019 2221 2524 2726
SGND 3
IOUT+
VOUT+
SGND 2
-RS485
+RS485
SGND 1
-RS485/RX
+RS485/TX
SERIAL
OUT 1
SERIAL
OUT 2
ANALOG
OUTPUT
OPTO OPTO

Table of Contents