5.4.3 Setting the load cells’ signal
S E G N 1
Itisthesensitivityvalueoftheloadcell.Themaximum
allowedsignalis3.5mV/V.
5.4.4 Setting the weighing system capacity
P O R T 1
Itisthecapacityoftheweighing system.Themaximum
capacityconsistsof100000divisions.
5.4.5 Setting the system resolution
S E N S 1
Thevaluecanbeselectedwithintherangefrom50to0.001
divisions.Thesystemresolutionisgivenbytheratiobetween
capacityandresolution.Seealsopoint2.2.1
5.4.6 Average settings
M E D I E 1
This parameter is used for the digital filtering of the weight
signal, in order to reduce the unwanted effects due for
example to mechanical vibrations that act on the weighing
system.Thehigheristheparameter’svalue,thegreateristhe
abilitytofilterunwantedoscillations,evenifthereisa
longer
delay in visualizing the variations of the weight signal. See
point2.2.4.
OFF
2
4
8
16
32
64
FIR 1
FIR 2
FIR 3
FIR 4