1569PT060EE1 Rev.7 Page56of62
Function05‐ForceSingleCoil
Allowsthehosttoforceasinglecoil.InT060EthecommandisusedtoissueaTAREorPOFresetcommand.
Thebelowisavalidexample:
ADDR FUNC COIL
#
HI
COIL
#
LOW
DATA
VALUE
HI
DATA
VALUE
LOW
CHECK
01
05
00
00
FF 00 8C3A
Thenormalresponseistoretransmitthequerymessage:
ADDR FUNC COIL
#
HI
COIL
#
LOW
DATA
VALUE
HI
DATA
VALUE
LOW
CHECK
01
05
00
00
FF 00 8C3A
6.4.1 T060E registers list
Register0isaspecialcodedregister(seedetails)
Weightvalues(gross,net)arecodedontwoconsecutiveregistersas2complementbinaryvalue.
Registersmarked“R”arereadonly
Register
Number
Function Type
0 Statusword R
12 Grossweightchannel1 R
34 Grossweightchannel2 R
56 Totalgrossvalue(CH1+CH2) R
78 Netweightchannel1 R
910 Netweightchannel2 R
1112 Totalnetvalue((CH1Tara)+(CH2Tara)) R
