1569PT060EE1 Rev.7 Page25of62
3.11 Optional analogue output
T060Eisequippedwithananalogueoutput(activetype)thatcanbeconfiguredeitherasanalogueoutputunder
voltageorasanalogueoutputundercurrent.
Itisrecommendedtouseashieldedcableandifrequired,theuseofseparatetroughs
inordernottoprejudicethe
properuseoftheequipmentandoptimalperformances.
Theshieldmustbeconnectedononesideonly.
INDICATION FUNCTION TERMINAL
VOU
T
Outputundervoltage 21
IOU
T
Outputundercurrent 20
SGND3 Common 19
3128 29 30
-S
+R
-R
3432 33
+S
3635 37
-A
+A
3938
-R
+R
-S
+S
-A
+A
LOAD CELL 2 LOAD CELL 1
232019 2221 2524 2726
SGND 3
IOUT+
VOUT+
SGND 2
-RS485
+RS485
SGND 1
-RS485/RX
+RS485/TX
SERIAL
OUT 1
SERIAL
OUT 2
ANALOG
OUTPUT
OPTO OPTO

Table of Contents