4-26 ADS TRITON+
®
Manual
depth threshold to a value below the lowest depth that typically occurs
at the location.
z Full Pipe The Full Pipe alarm triggers when the depth in the manhole
is measured at greater than or equal to the pipe height (as defined in the
location’s monitoring point properties).
z High Level Define the depth at which the monitor will trigger a High
Level alarm.
z High High Define the depth at which the monitor will trigger a High
High alarm. The High High value must set to zero (0) when this feature
is not in use, or greater than the value entered for the High Level alarm
when in use. ADS recommends setting the High High value at least 2
inches higher than the High Level value.
z Overflow This event indicates that the TRITON+ monitor’s internal
pressure sensor has detected the site is experiencing overflow conditions
where the flow is above the manhole rim.
NOTE: The TRITON+
desiccant tube must be installed outside the manhole if you are going to
use the Overflow Alarm.
z Battery Low Define the voltage at which the monitor will trigger a
battery low alarm. ADS recommends using the default value.