11-58 ADS TRITON+ Manual
Depth data indicates a surcharged pipe, but the pipe is
free flowing.
Physical offset may be incorrect.
Electronic offset may be incorrect.
Pipe height may be incorrect.
Verify the physical offset and the pipe height.
Verify electronic offset and
adjust if necessary.
Contact your regional ADS representative.
Replace the monitor if defective.
Ultrasonic depth readings are erratic.
Noise may exist in the sewer pipe.
dirty.
Flow may be choppy or foamy.
Check the flow conditions.
Check if the sensor is level and correct if necessary.
Mode in the sensor parameter
settings to determine whether the readings improve. If
the readings improve, reactivate the monitor with the
new setting.