EasyManua.ls Logo

Adtech CNC9640 - Page 148

Default Icon
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADTECH9 Series CNC Maintenance Manual
- 143 -
Range : 0~1
Unit : None
Authority : Super Admin
Default : 1
Effective time : Restart
Note : Pulse command format setting is to configure the mode of output pulse.
The compatible command format of the motor driver should be known in
advance.
0 Pulse + pulse
1 Pulse + direction
025 X Pulse Logic Dir Mode (restart)
Y Pulse Logic Dir Mode (restart)
Z Pulse Logic Dir Mode (restart)
4 Pulse Logic Dir Mode (restart)
B Pulse Logic Dir Mode (restart)
C Pulse Logic Dir Mode (restart)
Range : 0~1
Unit : None
Authority : Super Admin
Default : 1
Effective time : Restart
Note : Set pulse direction; if the controller direction is reverse to actual driver
direction, please modify this parameter to adjust the rotation direction of
motor.
026 X Ext Home ELevel
Y Ext Home ELevel
Z Ext Home ELevel
A Ext Home ELevel
B Ext Home ELevel
C Ext Home ELevel
Range : 0~1

Table of Contents

Other manuals for Adtech CNC9640

Related product manuals