ADTECH9 Series CNC Maintenance Manual
- 86 -
Move cursor to 007 or 008, and select corresponding operation menu;
Press [EOB], the system confirms, and performs backup or restore operation;
(6) The backup operation will generate the SYSCONF.BAK file in the root directory of disk D. Please save this
file for backup in the future.
(7) For restore operation, also save the SYSCONF.BAK file in the root directory of disk D. The system will
recognize this file automatically in the process of restoring.
9.5
Enter BIOS
(1) If the system has irreversible error and can’t be started, please enter BIOS to upgrade and maintain the
program;
(2) To enter BIOS, press the [Cancel] key after the controller is electrified and before the application is started;
after entering, a blue background interface pops up. If the BIOS requires password, a prompt pops up. Please
type the password to enter the BIOS.
(3) Enter BIOS to perform operations such as format disk C, D, and copy files from USB disk to upgrade;