ADTECH9 Series CNC Maintenance Manual
- 158 -
055 X servo spindle zero speed in-position input port
Y servo spindle zero speed in-position input port
Z servo spindle zero speed in-position input port
A servo spindle zero speed in-position input port
B servo spindle zero speed in-position input port
C servo spindle zero speed in-position input port
Range : 0~8888
Unit :
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the zero speed in-position input detection port after servo stop
during servo spindle detection (Note: This parameter is used when the
servo spindle is configured for this axis)
056 X servo spindle speed reaches the input port
Y servo spindle speed reaches the input port
Z servo spindle speed reaches the input port
A servo spindle speed reaches the input port
B servo spindle speed reaches the input port
C servo spindle speed reaches the input port
Range : 0~8888
Unit :
Authority : Super Admin
Default : Standard Pluse Mode
Effective time : Instant
Note : To set the input detection port when the servo speed reaches during servo
spindle detection (Note: This parameter is used when the servo spindle is
configured for this axis)
10.4
Management parameter (P3.)
001 Select administrator mode