- 170 -
Note : Set to 0: execute M30 instruction and do not turn off spindle running; set
to 1: execute M30 instruction and turn off spindle running.
007 Spindle Min Speed(rpm)
Range : 100~100000
Unit : rpm
Authority : Operation admin or higher
Default : 100
Effective time : Instant
Note : Spindle min speed setting
008 Second channel spindle max speed
Range : 1~100000
Unit : rpm
Authority : Operation admin or higher
Default : 24000
Effective time : Instant
Note : Set the maximum speed of second channel spindle.
009 Second channel spindle speed
Range : 1~24000
Unit : rpm
Authority : Operation admin or higher
Default : 6000
Effective time : Instant
Note : Set the speed of second channel spindle.
010 Spindle command S value invalid enable
Range : OFF ON
Unit :
Authority : Operation admin or higher
Default : OFF