Agilent N5181A/82A MXG Signal Generators User’s Guide 11
Signal Generator Overview
Rear Panel Overview
9. 10 MHz OUT
10. GPIB
This connector enables communication with compatible devices such as external controllers, and is
one of three connectors available to remotely control the signal generator (see also 11. LAN and
12. Device USB).
11. LAN
The signal generator supports local area network (LAN) based communication through this connector,
which enables a LAN- connected computer to remotely program the signal generator. The LAN
interface is LXI class C compliant; it does not support auto−MDIX. The signal generator is limited to
100 meters on a single cable (100Base- T). For more information on the LAN, refer to the
Programming Guide.
12. Device USB
Use this universal serial bus (USB) connector to connect a PC to remotely control the signal
generator.
Connector female BNC Impedance nominally 50Ω
Signal A nominal signal level greater than 4 dBm.
Connector Mini- B
USB Protocol Version 2.0