System Alarm Commands
Page 324 7210 SAS D, E, K OS Basic System Configuration
Guide
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.
Default 0
Values -2147483648 — 2147483647
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value raises above this threshold and reaches greater than or equal the rising-
threshold threshold value.
Default 0
Values -2147483648 — 2147483647
interval seconds — Specifies the polling period over which the data is sampled and compared with
the rising and falling thresholds.
Values 1 — 2147483647
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
Values log — In the case of log, an entry is made in the RMON-MIB log table for each
event occurrence. This does not create an OS logger entry. The RMON-MIB log
table entries can be viewed using the CLI command.
trap — In the case of trap, a TiMOS logger event is generated. The TiMOS logger
utility then distributes the notification of this event to its configured log
destinations which may be CONSOLE, telnet session , memory log, cflash file,
syslog, or SNMP trap destinations logs.
both — In the case of both, both a entry in the RMON-MIB logTable and a TiMOS
logger event are generated.
none — In the case of none, no action is taken.
Default both
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created. If
the first sample is greater than or equal to the rising threshold value and startup-alarm is equal to
rising or either, then a single rising threshold crossing event is generated. If the first sample is
less than or equal to the falling threshold value and startup-alarm is equal to falling or either, a
single falling threshold crossing event is generated.
Values rising, falling, either
Default either
Configuration example:

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS-D and is the answer not in the manual?

Alcatel-Lucent 7210 SAS-D Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS-D
CategorySwitch
LanguageEnglish

Related product manuals