System Alarm Commands
Page 326 7210 SAS D, E, K OS Basic System Configuration
Guide
Values log — In the case of log, an entry is made in the RMON-MIB log table for each
event occurrence.
This does not create a TiMOS logger entry. The RMON-MIB log table entries can
be viewed using the show>system>thresholds CLI command.
trap — In the case of trap, a TiMOS logger event is generated. The TiMOS logger
utility then distributes the notification of this event to its configured log
destinations which may be CONSOLE, telnet session , memory log, cflash file,
syslog, or SNMP trap destinations logs.
both — In the case of both, both a entry in the RMON-MIB logTable and a TiMOS
logger event are generated.
none — In the case of none, no action is taken.
Default both
Values log, trap, both, none
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created. If
the first sample is greater than or equal to the rising threshold value and startup-alarm is equal to
rising or either, then a single rising threshold crossing event is generated. If the first sample is
less than or equal to the falling threshold value and startup-alarm is equal to falling or either, a
single falling threshold crossing event is generated.
Default either
Values rising, falling, either
Configuration example:
memory-use-warn rising-threshold 500000 falling-threshold 400000 interval 800 rmon-
event-type log start-alarm falling
rmon
Syntax rmon
Context config>system>thresholds
Description This command creates the context to configure generic RMON alarms and events.
Generic RMON alarms can be created on any SNMP object-ID that is valid for RMON monitoring
(for example, an integer-based datatype).
The configuration of an event controls the generation and notification of threshold crossing events
configured with the alarm command.
thresholds

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS-D and is the answer not in the manual?

Alcatel-Lucent 7210 SAS-D Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS-D
CategorySwitch
LanguageEnglish

Related product manuals