Monitor CLI Commands
Page 70 7210 SAS D, E, K OS Basic System Configuration Guide
ipv6
Syntax ipv6 ipv6-filter-id entry entry-id [interval seconds] [repeat repeat] [absolute | rate]
Context monitor>filter
monitor>management-access-filter
Description This command enables IPv6 filter monitoring. The statistical information for the specified IPv6 filter
entry displays at the configured interval until the configured count is reached.
The first screen displays the current statistics related to the specified IPv6 filter. The subsequent
statistical information listed for each interval is displayed as a delta to the previous display.
When the keyword rate is specified, the "rate per second" for each statistic is displayed instead of the
delta.
Monitor commands are similar to show commands but only statistical information displays. Monitor
commands display the selected statistics according to the configured number of times at the interval
specified.
Parameters iv6p-filter-id — Displays detailed information for the specified IPv6 filter ID and its filter entries.
Values 1 — 65535
entry entry-id — Displays information on the specified IPv6 filter entry ID for the specified filter ID
only.
Values 1 — 65535
interval seconds — Configures the interval for each display in seconds.
Default 10 seconds
Values 3 — 60
repeat repeat — Configures how many times the command is repeated.
Default 10
Values 1 — 999
absolute — When the absolute keyword is specified, the raw statistics are displayed, without pro-
cessing. No calculations are performed on the delta or rate statistics.
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed instead
of the delta.
Sample Output
*A:7210SAS>monitor>filter# ipv6 10 entry 10 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for IPv6 filter 10 entry 10
===============================================================================
-------------------------------------------------------------------------------
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches : 0 pkts
Egr. Matches : 0 pkts

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS-D and is the answer not in the manual?

Alcatel-Lucent 7210 SAS-D Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS-D
CategorySwitch
LanguageEnglish

Related product manuals