EasyManuals Logo

Alcatel-Lucent 7750 SR OS Basic User Manual

Alcatel-Lucent 7750 SR OS Basic
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
Root Commands
7750 SR OS Basic System Configuration Guide Page 79
Parameters ip-filter-id — Displays detailed information for the specified filter ID and its filter entries.
Values 1 — 65535
entry entry-id — Displays information on the specified filter entry ID for the specified filter ID only.
Values 1 — 65535
interval seconds — Configures the interval for each display in seconds.
Default 5 seconds
Values 3 — 60
repeat repeat — Configures how many times the command is repeated.
Default 10
Values 1 — 999
absolute — When the absolute keyword is specified, the raw statistics are displayed, without
processing. No calculations are performed on the delta or rate statistics.
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed
instead of the delta.
Sample Output
A:ALA-1>monitor# filter ip 10 entry 1 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for IP filter 10 entry 1
===============================================================================
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------
At time t = 3 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------
At time t = 6 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------
At time t = 9 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
===============================================================================
A:ALA-1>monitor#
A:ALA-1>monitor# filter ip 10 entry 1 interval 3 repeat 3 rate
===========================================================================
Monitor statistics for IP filter 10 entry 1
===========================================================================
At time t = 0 sec (Base Statistics)
---------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
---------------------------------------------------------------------------
At time t = 3 sec (Mode: Rate)
---------------------------------------------------------------------------

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7750 SR OS Basic and is the answer not in the manual?

Alcatel-Lucent 7750 SR OS Basic Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7750 SR OS Basic
CategoryNetwork Router
LanguageEnglish

Related product manuals