Rockwell Automation Publication 1783-UM007G-EN-P - February 2017 41
Get Started Chapter 2
3. Click Submit.
The switch initializes its configuration for typical industrial
EtherNet/IP applications by running the global macro as described on
page 43. You can then log on to Device Manager for further
configuration or exit the application.
4. Turn off DC or AC power at the source, disconnect any cables to the
switch, and install the switch in your network.
5. If you used single-mode Express Setup or multi-mode Express Setup in
Short Press mode, refresh the computer IP address:
• For a dynamically assigned IP address, disconnect the computer from
the switch and reconnect the computer to the network. The network
DHCP server assigns a new IP address to the computer.
• For a statically assigned IP address, change it to the previously
configured IP address.
6. For Stratix 5400 and Stratix 5410 switches, synchronize the SD card
that came with the switch with the internal memory of the switch:
• To synchronize the SD card via Device Manager, see
page 65.
• To synchronize the SD card via the Logix Designer application, see
page 67.
After initial setup with Express Setup, you can change the settings if you want
to move the switch to another management VLAN or to another network. To
change Express Setup settings after initial setup, from the Admin menu in
Device Manager, choose Express Setup.
Enable SSH Check the checkbox to enable Secure Shell (SSH) sessions on the switch. You can use SSH to access the command-line interface (CLI) for switch
configuration. For more information about the CLI, see page 70.
Telnet, CIP and Enable Password
(optional), Confirm Password
The password that is used for Telnet and CIP security.
Same As Admin Password Sets the password that is used for Telnet and CIP security to the same user password specified under Network Settings.
Table 11 - Express Setup Fields (continued)
Field Description
IMPORTANT For 1783-BMS4S2SGL or 1783-BMS4S2SGA switches, make sure that
DC power is disconnected before disconnecting Ethernet cables.