191
3 Enter the SHOW STACK DETAIL command and examine the display for the entry that
has the same ID number of the member switch. Here is an example for the member
switch with the ID 2:
awplus# show stack detail
.
.
Stack member 2:
--------------------------------------------------------------
ID 2
MAC address e01a:ea20:8011
Last role change Thur Nov 23 21:15:20 2018
Product type x530L-10
Role Active Master
Status Ready
Priority 2
Host name awplus
S/W version auto synchronization On
Resiliency link status Not configured
Stack port2.0.7 status Down
Stack port2.0.8 status Down
.
.
Examine the entry for the following:
- The “Priority” value should be the same as the switch’s ID number. If they are not the
same, repeat “Configuring x530L-10GHXm Member Switches - Part II” on page 188.
Be sure to perform the STACK PRIORITY command and save your changes with the
write command.
- The “Stack port status” fields, the last two lines, should identify the selected optional
stack ports. If they identify the wrong ports, such as the default ports 9 and 10, repeat
“Configuring x530L-10GHXm Member Switches - Part II” on page 188. (The status of
the ports is Down because the stack ports are not cabled yet.)
5
Go to “What to Do Next” on page 199.
Table 30. Verifying the x530L-10GHXm Member Switches (Continued)
Step Description and Command

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis x530L Series and is the answer not in the manual?

Allied Telesis x530L Series Specifications

General IconGeneral
BrandAllied Telesis
Modelx530L Series
CategorySwitch
LanguageEnglish

Related product manuals