Storage 135
1201281 A | 24.07.2013
11.2.1 Draining the water tank and sprinkler
The water tank and the sprinkler unit must be drained.
1 Undo the quick-release coupling of the sprinkler hose.
1.1 Press the black plastic ring against the screw connection.
2 Pull the hose off the coupling.
3 Drain off the water.
4 Switch on sprinkler.
5 Let the water pump run briefly.
5.1 This pumps the remaining water out of the pipes.
Fig. 11-1 Draining sprinkling water
11.2.2 Removing the water filter
The plastic container must be removed if there is a risk of freezing. The water would
crack the container if it were to freeze.
1 Unscrew the plastic container (1) of the water filter.
Fig. 11-2 Water filter
NOTE Press the battery cut-off switch if storing for more than two days.
If no battery cut-off switch is fitted to your roller, remove the negative battery
cable from the battery if a standstill period of more than two weeks is expected.