153ASC 110
396265C
MAX
396262
MAINTENANCE MANUAL
Alternative lling through the tank ller
The alternative way of lling the hydrau-
lic circuit is only emergency solution!
In this way of lling it is necessary to cut
the next exchange interval to one half,
i.e. 1000 h or 1 year.
The cap of the tank ller is sealed. In case
of breaking the seal during warranty pe-
riod, the warranty expires.
NOTE
When lling via tank ller neck a large portion of used oil •
incl. dirt will remain within the vicinity, and hydraulic units’
life cycle will lower.
Order your lling device from your Machine manufacturer •
or dealer.
Rell the tank through the ller with specied type of oil up •
to the bottom of the strainer in the ller.
Rell oil in the tank to maximum and disconnect the lling •
device.
After owing out of approximately 15 l (4 US gal), close the •
drain cock.

Table of Contents