142 ASC110 / ASC130 / ASC150
3.6. Individual Operations of Maintenance
C
Every 20 Hours or Daily Every 20 Hours or Daily
3.6.9. Cleaning the water separator
Prepare a vessel for draining the settling.
Turn the separator valve (1) clockwise by 4 rotations
until it shifts down by approx. 25 mm (1”). Let fuel drain
until clean fuel starts to drain.
Then push the valve up and screw it in.
! NOTE !
If you drained more than 6 cl (2 ozs) of fuel, refill
fuel into the fuel filter according to chapter 3.6.20.
or deaerate the system according to chapter
3.6.37. This will prevent problems with starting.
Do not smoke nor use open fire when
working.
Do not drain the separator under running
engine.
Catch the drained fuel with sediments to a
suitable container.