143ASC110 / ASC130 / ASC150
MAINTENANCE MANUAL
Every 20 Hours or Daily Every 20 Hours or Daily
3.6.10. Checking warning and control devices
• Turn on switches (31, 32, 33, 34, 35, 36, 37), test the
horn, beacon and lights.
• Turn the ignition key to I position. Signal lamps (18, 19,
20, 21, 22, 23, 24) will light up.
• ECM signal lamps (18, 19, 20, 21) go off after 3
seconds.
• Start the engine - signal lamp (22) must go off.
• Start driving the machine and test the emergency
brake (5) and signal lights (23).
Continuously check devices and signal
lights during operation
Repair any indicated defects immedia-
tely!
Announce starting the engine by the
acoustic signal!
Check before starting of the engine that
nobody is endangered!
Give the acoustic signal before starting
driving the machine and wait for period
sufficiently long for all persons being
able to leave the area around the machi-
ne (area under the machine) in time!
Make sure that the area in front and in
the back of the machine is free and that
no persons are present in this area!