147ASC110 / ASC130 / ASC150
MAINTENANCE MANUAL
Every 250 Hours or Once in 3 MonthsEvery 250 Hours or Once in 3 Months
Beware of scalding when draining hot
oil. Let oil cool down to less than 50 °C
(122 °F).
Follow the fire safety measures!
Collect drained oil; do not let it soak into the
ground.
Used oil and filters are environmentally
dangerous waste - have them liquidated.
3.6.13. Checking the injection pump
Check tightness of the injection pump nuts.
NOTE
After refilling, start the engine for 2 - 3 min. Check
tightness of drain plug and filter.
Stop the engine, wait for approx. 5 min. until oil runs
down to the engine sump. Then check the level with oil
dipstick.
! NOTE !
Drain oil after stopping the operation, when it is
warm. Alternatively, warm engine up until the
temperature of cooling liquid reaches 60 °C
(140 °F).
Exchange oil after 6 months at the latest, if 250
hours of operation have not been reached by that
time.
Exchange oil in the interval that comes first.
Use recommended filters - see the specifications
manual or Spare parts catalogue.
Use recommended oil - see chapter 3.2.1.
Do not tighten the filter too tight, the thread and
sealing might get damaged.