173ASC110 / ASC130 / ASC150
MAINTENANCE MANUAL
2
Every 2000 Hours or Every 2 Years Every 2000 Hours or Every 2 Years
After closing the drain cock, fill cooling system with
new cooling liquid with ratio of 50% of water + 50% of
anti-freeze agent.
Fill it up to the upper edge of the level indicator. After
filling, wait for approx. 2-3 minutes until air goes off and
the circuit is filled. The maximum filling rate is 19 l/min
(5 US gal/min). Close the equaliser reservoir with the
pressure plug.
Start the engine and wait until the temperature rea-
ches 80 °C (175 °F). Check during your waiting for any
leakage of cooling liquid.
Stop the engine.
Check the level on the indicator (2). If the level is low,
refill cooling liquid to maximum.
Do not dismantle the pressure plug be-
fore the temperature of cooling liquid
falls lower than to 50°C (122°C). Bewa-
re of gushing of the coolant and scalding
when opening the pressure plug.
! NOTE !
Use cooling liquid according to chapter 3.2.3!
Follow the instructions of the manu-
facturer of anti-freeze fluid when chan-
ging coolant!
Protect your hands with gloves!
Use safety glasses or safety shield!
Collect used liquid and have it safely disposed
according to valid regulations!