86 ASC110/ASC130/ASC150/ASC200/ASC250
2.7. Controlling and operation of the machine
• After starting up, disconnect starting cables in reverse
order.
• If using a starting power unit without connected batte-
ries, do not disconnect the power unit before a battery
will be connected in the machine.
Do not connect the (-) pole cable to
the
(-) pole of the flat battery in the
started machine! When starting,
extensive sparkling may occur that
might ignite fumes generated by the
battery.
Prevent bare parts of starting cable
clips from mutual contact!
The starting cable connected to the
(+) pole of the battery must not
come into contact with electrically
conducting parts of the machine - risk
of short circuit.
Do not lean over batteries - beware of
electrolyte burns!
Keep away sources of fire (open
flames, lit cigarettes etc.)
Do not test whether wires are live by
touching the frame of the machine!
! NOTE !
Starting voltage of the external starting source
must be 24 V.
Keep the specified order of operations under all
conditions!
1. Connect one terminal of the (+) cable pole to the
(+) pole of the flat battery.
2. Connect the other terminal of the (+) cable pole to
the (+) pole of the battery in the supporting machi-
ne.
3. Connect one terminal of the (-) cable pole to the
(-) pole of the battery in the supporting machine.
4. Connect the other terminal of the (-) cable pole to
the part of the started machine that is securely
connected to the engine (or connect the terminal to
the proper engine block).