127ASC70
MAINTENANCE MANUAL
• Install the lter and tighten with your hand - as per lter
manufacturer’s data (by 2/3 turn once the lter bears on).
Fuel pre-lter
• Disconnect the connector of water separator sensor and
proceed in the same way like in the previous text. Connect
the sensor connector.
Fuel lter
Order number: 1194061
Note
Unless lters are lled with fuels when exchanging them, please
replenish fuel in both lters, refer to the Chapter named ”Fuel
System Deaerating“.
Use original lters required.
No smoking at work!
Do NOT tighten the lters with force.
Retain any fuel owing out.
Store used lters inside separate contain-
er, and hand over for their disposal.
• Fill the lter with pure fuel.