149ASC70
1
2
MAINTENANCE MANUAL
3.6.35. Fuel system venting
Deaerate (vent) the fuel system before the rst start:
• Unless fuel lters have been lled with fuel - upon lter re-
placement
• Upon fuel pump replacement
• Following fuel system repair
• Upon long term shutdown of the Machine
• When having run out of fuel from the tank
• Slacken air relief screw (1) on fuel pre-lter. Pump fuel via
the feed pump until clean fuel starts owing out, with no air
bubbles. Retighten the screw, and bleed the second lter via
the air relief screw (2).
Do NOT bleed with the hot engine, leak-
ing fuel may cause re.
No smoking at work on fuel system!
Retain any leaking fuel!