WARNING
WATER IN FUEL DETECTED
FMI 0SPN 97
396292D
MAINTENANCE MANUAL
Maintenance as required
3.6.33. Water separator cleaning
Yellow indicator lamp signal.
Code No. 97 VODA V PALIVU (WATER IN FUEL) will be dis-
played.
Turn the separator’s valve when water starts owing out.
! CAUTION !
If you drained over 60 cm
3
(0,63 quarts) of fuel, re-
plenish fuel into the fuel lter as per the Chapter
named “Deaerating”. In this way you will avoid prob-
lems concerning dicult starting.
No smoking at work.
NEVER drain separator during engine run.
Retain drained fuel incl. its deposit (sedi-
ments) in a suitable vessel.