138 ASC70
396241B
1
3
2
3.6. Lubrication and Maintenance
Every 2000 hours of operation (2 years)
3.6.28. Oil in the vibrator change
Exchange oil best after Roller operation
when the impurities are diused within
the medium.
Do NOT touch the gearbox and its adja-
cent parts if these are hot.
Drain oil when it gets cooled down below
50°C (122°F).
Avoid oil leakage into ground.
First carry out after 500 hours.
Place the Roller on at, paved area so that the drain plug on
drums LH side is in its lowest position, put an appropriate
vessel underneath this plug. Unscrew all the plugs and let
the oil run out. Once drained, reinstall the drain plug. Use
ller hole (2) to replenish oil recommended up to the edge
of inspection hole (3). Reinstall the remaining plugs.
The set of lters after 2000 operating hours can be
ordered under the order number 4-760107. For the
list of all spare parts, see the table in the end of this
publication.
3.6.27. Valve clearance adjustment
Call CUMMINS service department to adjust the engine
valves. Next valve adjustment will follow periodically after
2000 hours or after two years - for contact points, please re-
fer to Engine Operation and Maintenance Manual.