135ASC70
275103
1
396244A
MAINTENANCE MANUAL
3.6.25. Air conditioning compressor mounting
check
Check the strength of the compressor attachment and the
compressor bracket. Make sure that the belt does not spin. If
necessary, tighten the screws.
Belt
Order number: 1230933
Unscrew all plugs (1), (2), (3) and let oil drain.
Mount the drain plug (3) after draining is nished.
Rell recommended oil through the lling plug (1).
Check oil level in the checking opening (2). The oil level must
reach the lower edge of the opening or slightly ow out.
Mount the plugs (1) and (2), replace damaged plug sealings.
Drain oil once it gets cooled down below
50°C (122°F).