Chapter 4 — Cable & Antenna Analyzer Mode Commands
4-24 PN: 10580-00322 Rev. F S331L PM
[:SENSe]:CORRection:COLLect:INFO:STATus?
Query Description: Query returns 0 if calibration is not in progress, 1 if calibration is in
progress, 2 if calibration was aborted, 3 if cal-coefficients are being
calculated, or 4 if calibration has completed.
Example: To query calibration progress status:
:CORR:COLL:INFO:STAT?
[:SENSe]:CORRection:COLLect:INITialize
Cmd Description: Command to initialize an RF calibration with the current calibration
type.
Example: To initialize RF calibration:
:CORR:COLL:INIT
[:SENSe]:CORRection:COLLect:LOAD
Cmd Description: Perform ’Load’ step of calibration.
Example: To measure load:
:CORR:COLL:LOAD
[:SENSe]:CORRection:COLLect:OPEN
Cmd Description: Perform ’Open’ step of calibration.
Example: To measure open:
:CORR:COLL:OPEN
[:SENSe]:CORRection:COLLect:SAVe
Cmd Description: Complete an RF Cal and perform coefficient calculation.
Example: To complete a RF calibration and perform coefficient calculation:
:CORR:COLL:SAV
[:SENSe]:CORRection:COLLect:SHORt
Cmd Description: Perform ’Short’ step of calibration.
Example: To measure short:
:CORR:COLL:SHOR