Chapter 4 — Cable & Antenna Analyzer Mode Commands
4-24 PN: 10580-00322 Rev. F S331L PM
[:SENSe]:CORRection:COLLect:INFO:STATus?
Query Description: Query returns 0 if calibration is not in progress, 1 if calibration is in
progress, 2 if calibration was aborted, 3 if cal-coefficients are being
calculated, or 4 if calibration has completed.
Example: To query calibration progress status:
:CORR:COLL:INFO:STAT?
[:SENSe]:CORRection:COLLect:INITialize
Cmd Description: Command to initialize an RF calibration with the current calibration
type.
Example: To initialize RF calibration:
:CORR:COLL:INIT
[:SENSe]:CORRection:COLLect:LOAD
Cmd Description: Perform ’Load’ step of calibration.
Example: To measure load:
:CORR:COLL:LOAD
[:SENSe]:CORRection:COLLect:OPEN
Cmd Description: Perform ’Open’ step of calibration.
Example: To measure open:
:CORR:COLL:OPEN
[:SENSe]:CORRection:COLLect:SAVe
Cmd Description: Complete an RF Cal and perform coefficient calculation.
Example: To complete a RF calibration and perform coefficient calculation:
:CORR:COLL:SAV
[:SENSe]:CORRection:COLLect:SHORt
Cmd Description: Perform ’Short’ step of calibration.
Example: To measure short:
:CORR:COLL:SHOR

Table of Contents

Other manuals for Anritsu Site Master S331L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu Site Master S331L and is the answer not in the manual?

Anritsu Site Master S331L Specifications

General IconGeneral
BrandAnritsu
ModelSite Master S331L
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals