Chapter 3 — All Mode Commands
S331L PM PN: 10580-00322 Rev. F 3-7
:SYSTem:MBTemperature?
Query Description: Query returns motherboard temperature in degree C.
Example: To query motherboard temperature:
:SYST:MBT?
:SYSTem:OPTions?
Query Description: Query returns option string delimited by "/".
Example: To query full option string:
:SYST:OPT?
:SYSTem:PRESet
Cmd Description: Presets the application to its default state. Use *OPC? to block till
preset is complete.
Example: To perform preset:
:SYST:PRES
[:SENSe]:BASe:BRIGhtness <brightness-level>
[:SENSe]:BASe:BRIGhtness?
Cmd Description: Command sets the brightness level.
Query Description: Query returns the brightness level.
Param Type: Integer
Param Range: 0 to 10 in increments of 1, where 0 is 0% and 10 is 100% brightness
setting.
Default Value: 10
Example: To set brightness to 5:
:BAS:BRIG 5
[:SENSe]:BASe:IPaddress?
Query Description: Query returns the IP address in a special format. Return value
example: 2887436918 (to recover the actual IP address of
172.26.202.118, you need to convert the returned value to hex
AC1ACA76 and then take the resulting 4 numbers (2 characters each,
in hex) and convert them back to decimal.
Example: To query IP address:
:BAS:IP?

Table of Contents

Other manuals for Anritsu Site Master S331L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu Site Master S331L and is the answer not in the manual?

Anritsu Site Master S331L Specifications

General IconGeneral
BrandAnritsu
ModelSite Master S331L
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals