Chapter 4 — Cable & Antenna Analyzer Mode Commands
S331L PM PN: 10580-00322 Rev. F 4-9
:CALCulate:LIMit:MESSage OFF|ON|0|1
:CALCulate:LIMit:MESSage?
Cmd Description: Command sets the limit message state. Displays a Pass/Fail message to
indicate whether the trace crosses the limit line.
Query Description: Query returns the limit message state.
Param Range: OFF|ON|0|1
Default Value: OFF|0
Example: To set limit message on:
:CALC:LIM:MESS ON
:CALCulate:LIMit:MESSage:RESult?
Query Description: Query returns 0 if limit line says Fail. Otherwise, it returns 1 if limit
line says Pass.
Example: To get limit line Pass/Fail result:
:CALC:LIM:MESS:RES?
:CALCulate:LIMit:MODe
Cmd Description: Command changes the limit line to either Line or Segmented mode.
Example: To change the limit line mode
:CALC:LIM:MOD SEGM
:CALCulate:LIMit:PRESet
Cmd Description: Command presets the limit line to its default state.
Example: To perform limit line preset:
:CALC:LIM:PRES
:CALCulate:LIMit:TYPE 0|1
:CALCulate:LIMit:TYPE?
Cmd Description: Command sets the active limit line type. 0 for upper limit and 1 for
lower limit.
Query Description: Query returns the active limit line type.
Param Range: 0|1
Default Value: 0
Example: To set the active limit to lower limit:
:CALC:LIM:TYPE 1

Table of Contents

Other manuals for Anritsu Site Master S331L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu Site Master S331L and is the answer not in the manual?

Anritsu Site Master S331L Specifications

General IconGeneral
BrandAnritsu
ModelSite Master S331L
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals