[:SENSe]:FREQuency:CABLe:NAMe <"cable-name">
[:SENSe]:FREQuency:CABLe:NAMe?
Cmd Description: Command sets the cable name.
Query Description: Query returns the cable name.
Param Type: String
Param Description: Cable name
Default Value: NONE
Example: To set the cable to "AVA5-50 7/8":
:FREQ:CABL:NAM "AVA5-50 7/8"
[:SENSe]:FREQuency:STARt <frequency>{ Hz|kHz|MHz|GHz}
[:SENSe]:FREQuency:STARt?
Cmd Description: Command sets the start frequency.
Query Description: Query returns the start frequency in Hertz.
Param Type: Float
Param Description: Start frequency
Default Value: Model-dependent
Default Units: Hz
Example: To set the start frequency to 2 GHz:
:FREQ:STAR 2 GHZ
[:SENSe]:FREQuency:STOP <frequency>{ Hz|kHz|MHz|GHz}
[:SENSe]:FREQuency:STOP?
Cmd Description: Command sets the stop frequency.
Query Description: Query returns the stop frequency in Hertz.
Param Type: Float
Param Description: Stop frequency
Default Value: Model-dependent
Default Units: Hz
Example: To set the stop frequency to 2 GHz:
:FREQ:STOP 2 GHZ