Chapter 4 — Cable & Antenna Analyzer Mode Commands
4-20 PN: 10580-00322 Rev. F S331L PM
:DISPlay:WINDow:TRACe:Y[:SCALe]:TOP <amplitude>{dB}
:DISPlay:WINDow:TRACe:Y[:SCALe]:TOP?
Cmd Description: Command sets the display top value.
Query Description: Query returns the display top value.
Param Type: Float
Default Value: Return Loss = 0dB; DTF Return Loss = 0dB; Cable Loss = 0dB; VSWR =
3; DTF VSWR = 3; Transmission = 10dB; Phase = 225
Default Units: dB
Example: To set trace top value in Return Loss to 10 dB:
:DISP:WIND:TRAC:Y:TOP 10
:FORMat[:READings][:DATA] ASCii|INTeger,32|REAL,32
:FORMat[:READings][:DATA]?
Cmd Description: Command sets the data format type. ASCii and REAL returns data in
current unit. INTeger returns data with mdBm unit. This command
applies to :TRACe[:DATA]? and :CALCulate:DATA?.
Query Description: Query returns the data format type as ASC or INT, 32 or REAL, 32.
Param Range: ASCii|INTeger,32|REAL,32
Example: To set data format type to integer:
:FORM INT,32
Notes: INTeger,32 values are signed 32-bit integers in little-endian byte order.
This format returns the data in 4-byte blocks. REAL,32 values are
32-bit floating point numbers conforming to the IEEE 754 standard in
little-endian byte order. This format returns the data in 4-byte binary
format. The units are the current instrument units. Both INTeger and
REAL formats return a definite block length. Each transfer begins with
an ASCII header, such as #42204 for INTeger,32 and REAL,32. The
first digit represents the number of following digits in the header.
:FORMat[:READings][:DATA]:MULTiplier 1|1M
:FORMat[:READings][:DATA]:MULTiplier?
Cmd Description: Command sets the data format multiplier factor.
Query Description: Query returns the data format multiplier factor. If ’1M’ is passed as
argument, then query results for :TRACe[:DATA]? and
:CALCulate:DATA? will specify readings multiplied by 10^6. If ’1’ is
passed, then query results for :TRACe[:DATA]? and :CALCulate:DATA?
will specify read.
Param Range: 1|1M
Default Value: 1M
Example: To set data format multiplier to 1:
:FORM:MULT 1

Table of Contents

Other manuals for Anritsu Site Master S331L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu Site Master S331L and is the answer not in the manual?

Anritsu Site Master S331L Specifications

General IconGeneral
BrandAnritsu
ModelSite Master S331L
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals