Model 101/2100 Doors Service & Installation
TITLE:
99-13312-S001 Model 101/2100 Doors Service &
Installation
2. Transformer, wired as follows, will increase the 115 volt line voltage by 10% and the
applied heat by 20%.
3. Hot to H1-X3.
4. Neutral to H2-X1-X3.
5. Load for heaters X2-X4.
6. Transformer is rated for an 18 Amp load.
55. Frame Junction Box Wiring (Standard Production)
1. Remove cover.
2. Wires are marked as to application.
1-Black for frame heat.
1-Red for door heat.
1-White, common for Black and Red.
1-Blue for lights.
1-Blue/White common for lights.
1-Green/Yellow for ground.
56. Models 101 & 2100 Light Fixture Placement (Prior to 10/93)
Pre-wired lighting uses only 1-light ballasts. Non pre-wired uses 1- or 2-light ballasts.
Frame Breakdown – Each Frame Section with Full Flange