Model 101/2100 Doors Service & Installation
TITLE:
99-13312-S001 Model 101/2100 Doors Service &
Installation
70. Heat Load in BTU/Hr for Model 101 Low Temp Glass, Door Rail,
Frame Heaters and Standard Lighting
(Per Door, with Doors Closed @ 75°F Store Ambient)
MODEL 101 LOW
TEMPERATURE
(3-PANE HEATED REFLECTIVE GLASS – CASE TEMP -10°F)
24 x 36
874
1448
2022
2596
3170
24 x 67
1061
1821
2582
3343
4104
24 x 75
1112
1924
2736
3548
4360
26 x 67
1094
1887
2681
3475
4268
26 x 75
1145
1990
2835
3680
4525
28 x 75
1182
2064
2946
3828
4710
28 x 79
1207
2113
3020
3927
4834
30 x 36
932
1564
2196
2828
3460
30 x 67
1155
2009
2864
3718
4573
30 x 75
1212
2124
3036
3948
4860
30 x 79
1241
2183
3124
4065
5006
Add 10-20% to above values depending on door opening frequency.
71. Heat Load in BTU/Hr for Model 101 Normal Temp Glass, Door Rail,
Frame Heaters and Standard Lighting
(Per Door, with Doors Closed @ 75°F Store Ambient)
MODEL 101 NORMAL TEMPERATURE
(2-PANE NON-HEATED GLASS – CASE TEMP 38°F)