73. Electrical Information for Model 2100 Low Temp Heated Doors,
Frames & Standard Light Fixtures
Heater Amperages @ 120 Volts
NUMBER OF DOORS:
1
2
3
4
5
6
7
8
9
10
STYLE:
Low temp doors with heaters, 3-Pane Heated Reflective Glass (5.75 W/SQ. FT.)
APPLICATION:
Case Temperature -10°F, Humidity 74% or less, @ 75°F ambient.
24 x 36
1.11
2.19
3.24
4.23
5.29
6.48
7.47
8.46
9.52
10.58
24 x 67
1.84
3.37
4.94
6.54
8.14
9.88
11.48
13.08
14.68
16.28
24 x 75
1.98
3.65
5.38
7.18
8.95
10.76
12.56
14.36
16.13
17.90
26 x 67
1.97
3.71
5.40
7.17
8.86
10.80
12.57
14.34
16.03
17.72
26 x 75
2.12
3.97
5.77
7.58
9.38
11.54
13.35
15.16
16.96
18.76
28 x 75
2.16
4.11
6.15
8.08
10.06
12.30
14.23
16.16
18.14
20.12
28 x 79
2.33
4.23
6.28
8.28
10.30
12.56
14.56
16.56
18.58
20.60
30 x 36
1.30
2.60
3.82
5.15
6.28
7.64
8.97
10.30
11.43
12.56
30 x 67
2.07
3.91
5.69
7.63
9.39
11.38
13.32
15.26
17.02
18.78
30 x 75
2.23
4.23
6.23
8.24
10.19
12.46
14.47
16.48
18.43
20.38
30 x 79
2.37
4.46
6.51
8.70
10.74
13.02
15.21
17.40
19.44
21.48
NOTES: 1. All amperages are design amperages subject to the following tolerances: heated glass +/- 8%.
2. Although the amperages are calculated at 120 volts, all doors are designed to operate without
sweating when used within the application parameters with a voltage range of +/- 10%.
3. When calculating standard lamp amperage, add 1 lamp to the number of doors in the line-up and
multiply that number by the appropriate AMPS PER LIGHT value.
4. Design parameters do not make allowances for factors such as air leaks or unusual air flow
patterns within cases; therefore, some sweating may occur when upper limits of temperature or
humidity are encountered.
11
12
13
14
15
16
17
18
19
20
AMPS PER
LIGHT
24 x 36
11.70
12.69
13.82
14.81
15.87
16.92
17.98
19.11
20.10
21.16
NA
24 x 67
18.02
19.62
21.22
22.82
24.42
26.16
27.76
29.36
30.96
32.56
0.85
24 x 75
19.74
21.54
23.28
25.08
26.85
28.72
30.49
32.23
34.03
35.80
0.85
26 x 67
19.74
21.51
23.12
24.89
26.58
28.68
30.37
31.98
33.75
35.44
0.85
26 x 75
20.93
22.74
24.53
26.34
28.14
30.32
32.12
33.91
35.72
37.52
0.85
28 x 75
22.31
24.24
26.27
28.20
30.18
32.32
34.30
36.33
38.26
40.24
0.85
28 x 79
22.84
24.84
26.88
28.88
30.90
33.12
35.14
37.18
39.18
41.20
0.85
30 x 36
14.12
15.45
16.38
17.71
18.84
20.60
21.73
22.66
23.99
25.12
NA
30 x 67
20.95
22.89
24.47
26.41
28.17
30.52
32.28
33.86
35.80
37.56
0.85
30 x 75
22.71
24.72
26.61
28.62
30.57
32.96
34.91
36.80
38.81
40.76
0.85
30 x 79
23.91
26.10
27.99
30.18
32.22
34.80
36.84
38.73
40.92
42.96
0.85

Table of Contents