Model 101/2100 Doors Service & Installation
TITLE:
99-13312-S001 Model 101/2100 Doors Service &
Installation
REV.
B
Page 85 of 95
NUMBER OF DOORS:
1
2
3
4
5
6
7
8
9
10
STYLE: Normal temp doors with heaters, 3-Pane Non-Heated Glass or 2-Pane Reflective NHG
APPLICATION: Case Temperature 33°
F, Humidity 68% or less, @ 75
°
F ambient.
24 x 36
0.45
0.91
1.36
1.82
2.27
2.72
3.18
3.64
4.09
4.54
24 x 67
0.70
1.39
2.09
2.78
3.48
4.18
4.87
5.56
6.26
6.96
24 x 75
0.76
1.52
2.28
3.05
3.81
4.56
5.33
6.10
6.86
7.62
26 x 67
0.71
1.43
2.14
2.85
3.57
4.28
4.99
5.70
6.42
7.14
26 x 75
0.81
1.61
2.42
3.23
4.03
4.84
5.65
6.46
7.26
8.06
28 x 75
0.82
1.64
2.47
3.30
4.12
4.94
5.77
6.60
7.42
8.24
28 x 79
0.86
1.72
2.58
3.45
4.30
5.16
6.03
6.90
7.75
8.60
30 x 36
0.52
1.04
1.56
2.08
2.61
3.12
3.64
4.16
4.69
5.22
30 x 67
0.77
1.54
2.32
3.09
3.86
4.64
5.41
6.18
6.05
7.72
30 x 75
0.81
1.62
2.44
3.25
4.06
4.88
5.69
6.50
7.31
8.12
30 x 79
0.85
1.70
2.55
3.40
4.25
5.10
5.95
6.80
7.65
8.50
NUMBER OF DOORS:
1
2
3
4
5
6
7
8
9
10
STYLE: Normal temp doors with heaters, 2-Pane Heated Glass
APPLICATION: Case Temperature 31°
F, Humidity 80% or less, @ 75
°
F ambient.
24 x 36
0.80
1.61
2.41
3.21
4.01
4.82
5.62
6.42
7.22
8.02
24 x 67
1.36
2.73
4.09
5.46
6.82
8.18
9.55
10.92
12.28
13.64
24 x 75
1.52
3.04
4.55
6.07
7.59
9.10
10.62
12.14
13.66
15.18
26 x 67
1.44
2.88
4.32
5.76
7.20
8.64
10.08
11.52
12.96
14.40
26 x 75
1.58
3.16
4.73
6.31
7.89
9.46
11.04
12.62
14.20
15.78
28 x 75
1.65
3.31
4.97
6.62
8.27
9.94
11.59
13.24
14.89
16.54
28 x 79
1.73
3.47
5.22
6.96
8.70
10.44
12.18
13.92
15.66
17.40
30 x 36
0.97
1.94
2.91
3.88
4.85
5.82
6.79
7.76
8.73
9.70
30 x 67
1.56
3.12
4.68
6.24
7.80
9.36
10.92
12.48
14.04
15.60
30 x 75
1.71
3.41
5.12
6.83
8.54
10.24
11.95
13.66
15.37
17.08
30 x 79
1.79
3.57
5.36
7.15
8.93
10.72
12.51
14.30
16.08
17.86
NOTES: 1. All amperages are design amperages subject to the following tolerances: non-heated glass +/- 5%,
heated glass +/- 8%.
2. Although the amperages are calculated at 120 volts, all doors are designed to operate without
sweating when used within the application parameters with a voltage range of +/- 10%.
3. Design parameters do not make allowances for factors such as air leaks or unusual air flow
patterns within cases; therefore, some sweating may occur when upper limits of temperature or
humidity are encountered.