Model 101/2100 Doors Service & Installation
TITLE:
99-13312-S001 Model 101/2100 Doors Service &
Installation
b. Energy Management System (Sensor)
2. Mechanical:
A. Door Not Sealing? Check:
1. Magnetic gasket (Replace if necessary)
2. Torquemaster adjustment
3. Hold-Open
4. Defective frame plastic
5. Frame or door out of square
B. Door Will Not Close?
1. See instructions 2A, 1 through 5 above
C. Door Saw Toothed?
1. Door or frame out of square? (Square to the nearest 1/16” of net opening)
2. Torquemaster adjustment
3. Worn Hinge Pin hole?
4. Case not level?
5. Frame not shimmed properly?
3. Ballast/Lamps:
A. Lamps Will Not Start:
1. Ballast failure?
2. Incorrect ballast?
3. Incorrect wiring?
4. Incorrect bulb?
5. Poor contact between bulb and socket?
6. Case too old? (Lamps will usually light, but they will be very dim)
7. Incorrect socket wiring?
8. No ground?
B. Lamp Flickering:
1. Incorrect ballast?
2. Defective bulb?
3. Incorrect voltage?
4. Bulbs without shields?
C. Slow-Starting Bulb:
1. Improper wiring?
2. Poor lamp and socket connections?
3. Voltage too low?