EasyManuals Logo

ASCOM IPBL User Manual

ASCOM IPBL
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
TD 92579EN
15 February 2012 / Ver. H
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 5.0.x)
135
object-related alarms are automatically cleared after a timeout period of 30 minutes.
Active alarms are also cleared if the related object is restarted.
For a description of the attributes, see the table below.
Figure 30.
Attribute Description
Time The date and time when
the alarm is issued.
Code A unique number that identifies the alarm.
Click the
code to get more detailed information about the
alarm. For a list of possible codes and their
descriptions, see 10.2 Faul
t Code Descriptions on
page 142.
Severity It has three possible states:
Critical - Immediate action is
r
equired. It is displayed, for
example, if a managed object goes
out of service.
Major - Urgent action is required. It
is
displayed, for example, if the
capability of the managed object is
severely degraded.
Indeterminate - Level of severity
can
not be determined
Remote The IP Address of the object that r
eported the alarm.
Click the IP address to access the object.
Source The software module that reported the alarm.
T
ogether with the code it uniquely identifies an
alarm.
Description A textual description of the alarm.
8.21.4 Events
Under Diagnostics > Events is history of alarms and err
ors displayed including active
alarms. Click "Clear" in the top-right corner to clear the list of alarms and errors.
For a description of the attributes, see the table below.
Figure 31.
Attribute Description
Time The date and time when the alarm, error is issued or
clear
ed.
Type The status of the fault. It has four possible states:
Alarm - Alarms displayed in red are
a
ctive alarms
Alarm cleared - The alarm is already
clear
ed
Alarm timeout - The alarm
e
xceeded the timeout period
Error - Refers to faults that are not
a
ctive for a specific time.

Table of Contents