Configuration memory editor: show cfg
word instead of fuses
This option is recommended for advanced users only. It is
not saved in the UP configuration file for safety reasons.
Direct editing of fuses is understood as direct writing of a
configuration word value in the hexadecimal form.
When a non-translatable configuration word is entered,
the program leaves the unrecognized items unchanged
unless the user changes them him/herself. This typically
concerns CP fuses having several bits but only two
values.
Options Program settings Serial
numbers
Keyboard shortcut: Shift+F10
For further information on working with serial numbers
see Serial Numbers.
Serial numbers
This tab allows you to choose whether serial numbers are
to be used and if so then whether they should be read
from a file or computed and whether they should be
automatically written to the corresponding location.
Prepare S/N before programming
This option prepares a serial number in the selected
memory location before the actual device programming.
Find successor after programming
Once one programming procedure is successfully
completed, the system proceeds to the following serial
number. If this option is not activated, it is still possible to
proceed to the following number manually by clicking the
Next button on the Serial numbers tab see Serial
Numbers.
Prepare S/N after programming
This option causes that a serial number is prepared in the
selected memory location after the device programming.
Serial number interval
This defines by what value the following serial number
will be larger or smaller.
Log to file
By activating this option and by selecting a log file in the
field, information about correctly and incorrectly
programmed devices as well as the programming time is
saved in the selected file.
After project load set actual SN
according to the last in the log
When this option is enabled, the last programmed SN is
read from the log file and when the programming is
logged as errorless the next SN is computed from the
read value else the last SN is set again.
The log file has to exist and the last record has to contain
a SN.
This function can be useful when the serial numbers are
enabled and saving of UP project files is disabled, in such
a case the actual SN will not update in the project file on
program close.
Serial number length (the number of
characters)
This field determines how many characters the serial
number can hold. For example, 4 characters provide for
the serial numbers 0001 to 9999 in base 10 (i.e. in
decimal form).
Number base
This option defines the base of the serial number
characters. Base 10 and base 16 are available (i.e. the
decimal and hexadecimal forms).