5.3. Communication error code (Serial bit)
The serial response gives an error code in the form of an integer value. You have to convert
the value to binary to obtain the error bit affected. For example a response {Er00004} means
that the system doesn’t recognized the first character of the command.
Binary
Error Bit
Message
[00001]
0
Message string syntax error!
[00002]
1
String to integer data convert error! , even/off according to read/write
[00004]
2
Unknown first character of command!
[00008]
3
Unknown second character of command!
[00016]
4
Parameter value error!
[00032]
5
Sequence vibration duration value 0 error !
[00064]
6
Access to the vibration set or sequence ID 26 error!
[00128]
7
« not used »
[00256]
8
Receive buffer is full!
[00512]
9
Receive end of message “}” but receive buffer is full!
[01024]
10
Receive end of message “}” but missing begin of message “{“!
[02048]
11
[04096]
12
Framing error detected!
[08192]
13
Parity error detected!
[16384]
14
Overflow error detected!
[32768]
15
Receive complete message timeout control!
Table 5-2: communication error code

Table of Contents

Other manuals for Asyril Asycube 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Asyril Asycube 530 and is the answer not in the manual?

Asyril Asycube 530 Specifications

General IconGeneral
BrandAsyril
ModelAsycube 530
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals