Asycube - Asyril SA
Programming Guide
34/83
5.3. Communication error code (Serial bit)
The serial response gives an error code in the form of an integer value. You have to convert
the value to binary to obtain the error bit affected. For example a response {Er00004} means
that the system doesn’t recognized the first character of the command.
Message string syntax error!
String to integer data convert error! , even/off according to read/write
Unknown first character of command!
Unknown second character of command!
Sequence vibration duration value 0 error !
Access to the vibration set or sequence ID 26 error!
Receive end of message “}” but receive buffer is full!
Receive end of message “}” but missing begin of message “{“!
Receive complete message timeout control!
Table 5-2: communication error code