5.4.9.2. Asycubes 240 and 530: Outputs activation
Code
Label
Command
Response
Remark
BA..Z
Outputs activation for a
time [ms]
{BF100}
{BF100}
Activation F activate for 100ms
BA0..Z0
Outputs activation forever
{BF0}
{BF0}
Activation F activate forever. Use the
command HB to stop the activation.
BA..Z
Outputs activation for a
pre-defined delay
{BF}
{BF}
Delay depends on selected Activation. In
this case the delay is equal the register
1250 value. If value = 0 -> forever
B?
Read selected Output
activation
{B?}
{B?:F}
Activation F is selected. The selected
output activation is the last activation
executed.
B??
Read selected Output
Activation and state
{B??}
{B??:F3}
Activation F is selected and the state is 3.
States:
0: Outputs disabled
1: Outputs enabled but stopped
3: Activating
!: Undefined actuator state
BA..Z ?
Read Output Activation
state
{BF?}
{BF:0}
State of Activation F is 0.
States:
0: Outputs disabled
1: Outputs enabled but stopped
3: Activating
!: Undefined actuator
Table 5-15: outputs activation commands

Table of Contents

Other manuals for Asyril Asycube 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Asyril Asycube 530 and is the answer not in the manual?

Asyril Asycube 530 Specifications

General IconGeneral
BrandAsyril
ModelAsycube 530
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals