5.4.11. Flash Operation
Code
Label
Command
Response
Remark
DF
Data Flash All in memory
{DF}
{DF}
100’000 Program Cycles
DG
Data Flash Global Parameters
{DG}
{DG}
DS
Data Flash Sequences
{DS}
{DS}
DV
Fata Flash Vibration Set
{DV}
{DV}
Save only the current vibration set
DE
Data Erase Memory
{DE}
{DE}
** only developer (Asyril)
DR
Data Restore Memory
{DR}
{DR}
* only integrator
DY
Restore Data with Factory
values
{DY}
{DY}
* only integrator
DP
Restore current vibration set
data and all sequences data with
Factory values
{DP?}
{DP?:0}
* only integrator
D..?
Data Flash Memory State
{DF?}
{DF?:0}
States:
0: Operation completed
1: Operation in progress
16: Flash operation busy
128: Operation need password
Table 5-17: flash operations commands
When something is saved in the flash memory, the status led flashes quickly during the whole saving
process. If the user tries to save in flash during this time, an error answer is sent (error 80).
The duration of the saving process is 8s or 16s alternating.
During the saving process, the user can use the product, but cannot change any value or select
another vibration set.
NOTE :
The Asycube saves automatically the global parameters every 20 minutes (equivalent to
{DG} command). This automatic saving process has no impact on the functionning of the
Asycube.

Table of Contents

Other manuals for Asyril Asycube 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Asyril Asycube 530 and is the answer not in the manual?

Asyril Asycube 530 Specifications

General IconGeneral
BrandAsyril
ModelAsycube 530
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals