6.3. Asycube Modbus Register Table
Asycube data can be accessed via Modbus TCP through Holding Registers. The Register Table presented in this section describes all the Asycube
Holding Registers. All Holding Registers are 2 bytes long. Their type is generally a WORD or an UNSIGNED_INT16. Some of the Holding Registers can
have negative values (see Data Range column in the Register Table). In this case, their type is SIGNED_INT16. All registers are either Read-only or
Write-only (see Read/Write column in the Register Table). This section presents the Holding Registers, which have been placed in different address
zones. The registers addresses are shown with the address offset of the zone and the relative address of the register (e.g. “64+3” means that the
register is in the zone starting at address 64).