Asycube - Asyril SA
Programming Guide
© Copyright Asyril S.A.
000.101.572
Version : A1
62/83
Address
(decimal)
Holding Register name
Read/
Write
Data Range
Comments
address trigs a write of the value given in the Holding Register
HR_READ_WRITE_PARAMETER_WRITE_VALUE (Address 30).
Note: no error occurs when trying to write in a forbidden Asycube register.
30
HR_READ_WRITE_PARAMETER_ADDRESS
W
0 to 65535
The parameter read/write trigged with HR_READ_WRITE_PARAMETER_TRIG
needs this parameter address. More information in Chapter 4 and in the row
above.
31
HR_READ_WRITE_PARAMETER_WRITE_VALUE
W
0 to 65535
The parameter write trigged with HR_READ_WRITE_PARAMTER_TRIG needs
this Holding Register value to be written in the parameter.
32
HR_FLASH_OPERATIONS
W
0 to 15
The 4 first bits are used to start flash operations. A rising edge on a bit trigs the
corresponding flash operation:
0b0001: Flash All in memory
0b0010: Flash Global Parameters
0b0100: Flash Sequences
0b1000: Flash Vibration Set
More information in Section 5.4.11.
Table 6-1: Control Holding Registers, offset=0

Table of Contents

Other manuals for Asyril Asycube 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Asyril Asycube 530 and is the answer not in the manual?

Asyril Asycube 530 Specifications

General IconGeneral
BrandAsyril
ModelAsycube 530
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals